Close
Switzerland — EN
Adjust
Menu

Air Fire Tech Rorcol AV60 System

Fire protection collars Rorcol AV60 to close aluminium multi-layer (MLCP) and metal pipes with and without insulation and cables/hoses. It is a 60 mm deep stainless steel housing with internal, three-dimensionally expanding intumescent (from about 150 °C) and an integrated mounting clip extension for spanning large annular gaps.

Suitable for the construction and installation, oblique penetrations, multiple services, omega-use and many other special applications. Shaft walls from 40 mm thickness, solid and stud (flexible) walls from 100 mm, laminated timber ceiling and...

↓ Read more

Fire protection collars Rorcol AV60 to close aluminium multi-layer (MLCP) and metal pipes with and without insulation and cables/hoses. It is a 60 mm deep stainless steel housing with internal, three-dimensionally expanding intumescent (from about 150 °C) and an integrated mounting clip extension for spanning large annular gaps.

Suitable for the construction and installation, oblique penetrations, multiple services, omega-use and many other special applications. Shaft walls from 40 mm thickness, solid and stud (flexible) walls from 100 mm, laminated timber ceiling and solid ceilings from 150 mm, EPS lightweight concrete from 200 mm (for installation in EPS lightweight concrete blocks the use of the Rorcol installation aid required). Tested and classified in various mineral wool batts systems for walls and ceilings.

All types of RORCOL fire protection sleeves can be used with zero distance between themselves and with 50 mm distance from Air Fire Tech fire barriers and fire dampers. Tested according to EN 1366-3, EI90 / EI120 classified according to EN 13501-2 and approved acc. ETA 13/0758. CE marking according to ETAG 026 Part 2.

Extra information
  • Housing made of stainless steel
  • Extensive range of applications and special applications and multiple services in one collar
  • Aluminium multi-layer to diameter Ø 63 mm
  • Omega-application possible to Ø 80 mm per service
  • Integrated mounting clip extension for spanning large annular gaps
  • Zero distance between the collars
  • 50 mm from the Air Fire Tech fire barriers and fire dampers
  • Approved installation in shaft walls from 40 mm thickness
  • Installation approved in laminated timber constructions
  • Approved for installation in walls and ceilings